Measurement of Tablet Hardness Using Different Techniques

Tablet hardness, also known as tablet crushing strength, is an essential parameter that measures the mechanical strength and integrity of a tablet. It is an important quality control parameter in tablet manufacturing. Several techniques are available to measure tablet hardness. Here are some commonly used methods:

1. Manual Hardness Testing

Manual hardness testing involves using a tablet hardness tester, also known as a tablet hardness tester, to measure the force required to break a tablet. The tablet is placed between two platens, and force is applied until the tablet fractures. The force required to break the

tablet is recorded as the tablet hardness. This method is relatively simple and widely used in small-scale manufacturing and research settings. However, it is labor-intensive and may have higher variability compared to automated methods.

Pharma Tip:  Conducting Particle Size Analysis for Granules Used in Tablets

2. Automated Hardness Testing

Automated hardness testers are advanced instruments that measure tablet hardness automatically. The tablet is placed in the instrument, and a pre-determined force is applied to break the tablet. The instrument records the force required to break the tablet, providing a more accurate and consistent measurement compared to manual testing. Automated hardness testers are commonly used in large-scale tablet manufacturing, where high throughput and precise measurements are essential for quality control.

3. Diameter Measurement and Crushing Strength Calculation

In this method, the tablet diameter is measured using a caliper or micrometer, and the tablet’s hardness is calculated using a formula that relates tablet diameter and crushing strength. The formula used for the calculation depends on the tablet shape and geometry. While this method provides an indirect measurement of tablet hardness, it is less accurate than direct hardness testing methods.

Pharma Tip:  How to Formulate Coated Tablets for Controlled Release

4. Disintegration Test for Effervescent Tablets

For effervescent tablets, the hardness can be indirectly assessed by performing a disintegration test. Effervescent tablets are designed to dissolve and disintegrate rapidly in water to release carbon dioxide and the active pharmaceutical ingredient. The time taken for complete disintegration in water is measured, and it correlates with the tablet’s hardness. Faster disintegration times indicate higher tablet hardness.

5. Near-Infrared (NIR) Spectroscopy

Near-infrared (NIR) spectroscopy is an advanced analytical technique used for rapid and non-destructive analysis of pharmaceutical products, including tablets. NIR spectroscopy can be used to predict tablet hardness by correlating NIR spectra with tablet hardness data obtained from reference methods like manual or automated hardness testing.

Pharma Tip:  How to Stabilize Tablets Containing Hygroscopic Ingredients

Conclusion

Tablet hardness is a critical parameter in tablet manufacturing, as it reflects the tablet’s mechanical strength and resistance to breakage. Various techniques are available to measure tablet hardness, ranging from manual and automated hardness testing to indirect methods like diameter measurement and disintegration tests for effervescent tablets. Selecting the appropriate hardness testing method depends on the scale of production, precision requirements, and the specific characteristics of the tablets being tested.

Tablets Tags:API tips, Batch processing, Capsules, Chewable tablets, Cleanroom technology, Direct compression, Disintegration time, Drug production, Drug stability testing, Dry granulation, Effervescent tablets, Enteric-coated tablets, Excipients, Formulation development, GMP (Good Manufacturing Practice), Immediate-release tablets, Manufacturing guidelines, Pharmaceutical equipment, Pharmaceutical manufacturing, Pharmaceutical packaging, Pharmaceutical processes, Pharmaceutical safety, Process validation, Quality control in pharmaceuticals, Regulatory compliance, Tablet compression, Tablet defects, Tablet formulation, Tablet friability, Tablet hardness, Tablet lubricants, Tablet size and shape, Tablet types, Tablet uniformity, Tablets, Wet granulation

Post navigation

Previous Post: What are the potential issues with medical device materials compatibility?
Next Post: What is the role of excipients in capsule manufacturing?
  • Aerosol Formulations
  • Capsules (Hard & Soft Gelatin)
  • Drug Discovery
  • External Preparations
  • GLP Guidelines
  • GMP Guidelines
  • Medical Devices
  • Parenteral Drug Manufacturing
  • Pharma Quality Control
  • Pharma Research
  • Schedule M
  • Solid Dosage form
  • Solid Oral Dosage Forms
  • Tablets
  • Tablets

Copyright © 2025 Pharma.Tips.

Powered by PressBook WordPress theme